share Image
Description
  • Magnetic Starter
  • Type Full Voltage, Magnetic, Non-Combination, Non-Reversing
  • Power Rating/Voltage 7-1/2 HP at 200/208 VAC
  • Current Rating 27 Ampere
  • Phase 3
  • Coil Voltage 200 to 208 VAC at 60 Hz
  • Size NEMA 1
  • Enclosure Type NEMA 1
  • Overloads 3-Phase 3-Leg Block Thermal Overload Relay
  • Construction Standard NEMA
  • Includes Holding Interlock, Pressure Terminal for Line and Load Connection

Features / Benefits

  • Magnetic Motor Starters May be Used for Starting Full Voltage, Non-Reversing, Single Speed AC Motors Upto 1600 Horsepower, 600 Volts Maximum, Providing Protection to the Motor Against Running or Stalled Overloads
  • Their Compact Size and Ease of Wiring Make them Especially Suitable for Motor Control Centers, Custom Type Control Panels and Switchgear Equipment
  • Toolless Contactor Disassembly (Sizes 00-4) Allows Quick Access for Inspection and Maintenance
  • Just Release Two Retainers and Pull a Clip to Get at Magnet, Coil and Contacts
  • Saddle Clamp Terminals (Sizes 00-1) Accommodate Ring, Spade and Stripped Wire Leads and Carry Permanent Stamped-In Identification
  • Staggered Arrangement Makes Wiring Easier and Helps Prevent Shorting Between Phases
  • Current Carrying Components Contact Tips Are Weld Resistant Silver Cadmium Oxide (Fine Silver on Sizes 00 and 0 Only)
  • Contacts Are Installed in a Wedge Configuration for Positive Make with Minimum Bounce
  • Class 20 Overload Protection
  • Visual Trip Indicator with Manual Reset to Avoid Surprise Restarts
  • Reset Occurs on Arm Upstroke So a Tripped Condition Cant be Overridden by Holding the Arm Down
  • Manual Weld Check Provides a Convenient Test Against Welding of Overload Relay Contacts
  • Just Depress the Weld Check Operator to Trip the Relay, Run a Simple Continuity Test Across the Relay Contacts, then Depress the Manual Reset to Return the Starter to Service
  • Optional Isolated No Contact on the Overload Relay Provides Means of Direct Interface with Programmable Controller or Computer to Monitor Performance and Diagnose Faults
  • Dual Bimetals Anticipate Overloads, Responding to Rising Current and Temperature with Faster Tripping on Severe Overloads for Better Motor Protection
  • Trip Points Are Factory Calibrated for Accuracy
  • +/-10 Percent Trip Adjustment by Turning a Dial in the Overload Relay Face Allows Tuning the Protection to the Motor on the Spot

CR306C123 GE SIZE-1 3P ENCLOSED NEMA-1 MAGNETIC CONTACTOR - 208V COIL

$352.47 / EA
Availability: Currently out of stock
SKU
CR306C123
Manufacturer:
  General Electric
By placing an order you agree to Terms & Conditions
EA
More Information
Commodity Level DescripNEMA Non-Combination Starters
Brand NameSeries CR306
ManufacturerGeneral Electric
UPC783166357675
UNSPSC39121521
Commodity Code41350
Power Rating/Voltage7-1/2 HP at 200/208 VAC
SizeNEMA 1
Phase3
Overloads3-Phase 3-Leg Block Thermal Overload Relay
TypeFull Voltage, Magnetic, Non-Combination, Non-Reversing
Current Rating27 Ampere
Construction StandardNEMA
Coil Voltage200 to 208 VAC at 60 Hz
Enclosure TypeNEMA 1
Additional InfoIncludes Holding Interlock, Pressure Terminal for Line and Load Connection
Resources
Add SpecAdd Spec
install instinstall inst
Specification SheetSpecification Sheet
Related Products